Range | Model | TB min - TB max | TH fix | | K-S 4Z | 600 - 850 | 2000 | Conforms to lift directive 95/16/CE and EN81-1/2: 1998 Ø Clear opening limits (TBxTH mm) 95/16EC - EN81-1/2: 1998 Ø Overall Dimensions for doors (125 KB) Ø What does it mean TBxTH and K2L, S2L etc...? HIGHLIGHTS • This Product Line follows the concept of the Sematic 2000 C (Compact) and in addition has a reduced dimension in the width of the car door and landing door headers • For a 600 mm TB the car door header dimension is only 960 mm wide, and the landing door header is only 980 mm wide. In a "1 meter shaft" you can have a 600 mm TB • For a S4Z the thickness of the complete door, full frame included, is only 110 mm (the total package of car door, landing door and running clearance is only 215 mm thick) | CAR DOOR - Car door operator with 32 Vdc DC motor with optical Encoder controlled by an electronic card with microprocessor (SDS© DC-PWM )
- Power supply voltage: 90-290 Vac (115 V - 20%, 230 V + 26%), 50-60 Hz with an integrated switching transformer
- Installed power: 200 VA
- Emergency operation at 24/36 Vdc
- Operating temperature range: from -10 °C to +60 °C
- Operating humidity range: from 20% to 80% non-condensing
- Self learning - cycle at the first installation in order to acknowledge the door dimension and form the opening and closing curve
- Opening and closing speeds are separately adjustable
- Integrated adjustable device for reopening doors after detecting the presence of an obstacle
- Header with steel plate min. thickness 2 mm (protected by primer - powder paint RAL 7032)
- Fix coupling skate up to TB=650 , moving coupling skate from TB=700
- 6 mm fixing brackets to cabin with second fixing point
- Single skinned panels with steel plate min. thickness 1,5 mm (protected by primer - powder paint RAL 7032)
- Long life guide shoes for panels
- Aluminium bottom track
- Lock release key for landing doors
- Without car door apron
- Export type cardboard shock resistant packages
| | LANDING DOOR - Certified locking according to EN81-1/2: 1998 and Lift Directive 95/16/EC
- Frame complete with side posts
- Electrical Safety Switches with IP54 rating are installed as standard
- Single skinned frame and panels minimum thickness 1,5 mm (protected by primer - powder paint RAL 7032)
- Long life guide shoes for panels
- Aluminium bottom track and cill
- Upper, lower and side brackets for wall or frame fixing
- With landing door apron
- Export type cardboard and wooden packages